This product complies with the following EC Directives
:
Electro-Magnetic Compatibility Directive.
(EMC) (89\336\EEC), (92\31\EEC)
Low Voltage Directive.
(LVD) (73\23\EEC), (93\68\EEC)
Danfoss Randall Ltd
Ampthill Road, Bedford, MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Website: www.danfoss-randall.co.uk
2 ON/OFFs
2 ON/OFFs
7 DAY or 24 HOUR
24 HOUR
3 ON/OFFs
3 ON/OFFs
5/2 DAY
7 DAY
SW.1
SW.2
SW.3
SW.4
Installation Instructions
Product overview
The TS715 is an electronic single channel timeswitch with voltage free
contacts making it ideal for combination boiler applications. It can be set at
time of installation for 7 day, 5/2 day or 24 hour operation. In addition the
installer can select between 2 or 3 sets of On/Off events each day. All models
in the range incorporate a permanently lit back light.
Installation
1. The product should only be installed by a qualified electrician or
competent heating installer. The installation must be in accordance with
the current edition of the IEEE wiring regulations
2. From the top left hand corner of the wallplate, there must be
clearances of at least 140 mm to the right, 15mm to the left, 30mm above
and 100mm below in order to mount the plug-on module.
3. The wallplate must be securely mounted either directly to the wall
using suitable wood screws or to a flush mounted 1-gang electrical
accessory box using M3.5 screws.
4. Cable access can either be from behind for concealed cabling, or
from below for surface cabling. If surface cable is used, cut out cable
access slot on plug-on module prior to mounting the module.
5. For wiring connections refer to diagram below. TS715 models are
double insulated and do not require an earth connection, however a parking
terminal is provided on the wallplate. This is clearly marked with an Earth
symbol.
6. Prior to mounting the plug-on module, DIL switches on the rear of
the plug-on module must be set. See table below for available options.
7. Mark the INSTALLER SETTING tick box on the inside flap label to
notify user in which mode their unit is set (24hr, 5/2 day or 7 day).
8. Mount plug-on module to wallplate by locating tabs on top of wallplate
in apertures on rear of module, hinge down and press firmly to wallplate
before tightening securing screws on bottom of wallplate.
TS715 (3066 12/01)
Diagram 1. - Wiring
Diagram 2. - DIL Switch Settings
Fault Check List
Event ON/OFF Mon - Fri * Sat - Sun
1 1st ON 6:30 7:30
2 1st OFF 8:30 10:00
3 2nd ON 12:00 12:00
4 2nd OFF 12:00 12:00
5 3rd ON 17:00 17:00
6 3rd OFF 22:30 22:30
* Each day if set in 24 hour mode
Product specification
Power supply 230 V ac, ±10%, 50/60 Hz
Switching action 2 x SPDT internally linked
Switch rating 230 V ac, 3(1)A
Battery back-up 24 hours minimum
Max. temperature 45°C
Programme resolution 1 minute
Dimensions, mm (W, H, D) 135 x 88 x 32
Design standard EN 60730-2-7
Control Pollution Situation Degree 2
Rated Impulse Voltage 2.5kV
Ball Pressure Test 75°C
Factory Presettings
Part No. 38035 Iss.1 03/03