temperature. Start-up of the function can be related to
the power supply tariffs switch-over, either via time or
external command. The advantage consists in a
possibility to accumulate heat under better conditions, i.
e. when the air temperature is higher.
Bivalent source:
Supports electrical cartridges in flow or tank
Supports exernal sources (existing gas, electrical or
other boilers)
Three-level or single-level bivalence control
Heating system:
Solely equithermal control (acc. to the ambient
temperature only)
Space temperature control
Equithermal control in relation to space
One controller can control up to 2 heating circuits and
one pump circuit
Each heating circuit can be controlled independently via
its own space unit
Existing thermostats with ON/OFF modes can be used
More heating circuits can be added via the RVS zone
controllers
Possible integration with master controllers, i. e. control
of heating circuits per room
Hot water heating
Water heated in the tank with a separate boiler
Water heated in the surge tank with a floating boiler
Internal exchanger or external exchanger for boilers
without an internal exchanger or with insufficient capacity
Flow heating
Force heating
Combination with solar heating
Control of electrical heater in the boiler or external source
for hot water heating
Function of heat transfer between the surge tank and
boiler (typical situation: the tank is heated by the solid
fuel boiler or hot water wood stove)
Solar system:
Over 50 ways of connection
Definition of 3 off-takes (hot water heating, surge tank,
swimming pool)
Integration with the heat pump (can meanwhile work as a
secondary source for hot water heating)
Swimming pool heating:
Supported
Wood stove:
In case the tank is heated from the stove, the heat pump
is off
Function of overheated tank cooling
If combined with another RVS, the wood stove or solid
fuel boiler circulation pumps can be controlled directly,
including other functions, e. g. source extinction
monitoring.
Cooling:
Supports both passive and compressor cooling
Supports heating and cooling in the both two-pipe and
four-pipe networks
Supports alternating cooling and heating of hot water or
swimming pool
Supports passive cooling at ground to water systems
Dew point check
Dehumidifier control
Cascade:
Standard control supports connection up to 16 heat
pumps or other sources in the cascade mode
Various types of sources are supported in the cascade
(gas, electrical or fuel solid boilers)
Gas boilers with Siemens control can be connected with
our heat pumps to the cascade. The following brands are
available on the Czech market: Geminox, Brötje, Baxi
and Viadrus, equipped with the LMU units.
Other functions:
Entry of ripple control (electrical heating blocking)
Entry of external command on heat 0 – 10 V, mode
switching, heat pump start-up...