Temperature sensors
Outdoor
Room
Surface
Immersion
Accessories
Socket for wall mounting
Connector set for panel mounting
Analog clock for ECL Comfort
100B and 100M
Room panel, ECA 60 with
built-in room temperature sensor
Room panel, ECA 62
(as ECA 60 but with humidity sensor)
Remote control, ECA 61
Remote control, ECA 63
(as ECA 61 but with humidity sensor)
Relay module – for extended
functionality
LON module – for network
connection
RS232 module – for PC connection
Select Your ECL Comfort
( )
Accessories for the controller
series ECL Comfort
ECL Comfort
*1: Some systems need an optional relay module (ECA 80)
*2: Only together with 'ECL Comfort 301 with ECA 83'
1) Control of a circulation pump and an alarm output signal
2) Control of a DHW pump or change-over valve
3) Control of two additional burner steps
4) Module to communicate the flow and energy parameter from a heat meter
5) Module to monitor temperatures and data points from the controller
ECL Comfort 100 ECL Comfort 200 ECL Comfort
300/301
C37/C47
1)
, C55
2)
, C75
3)
C37/C47/C66
4)
C66
5)
ECA 60/62, Room panel
ECA 61/63, Remote control
ECA 80, 2 x relay
ECA 82, LON module
ECA 84, M-Bus module
ECA 86, I/O and alarm option
ECA 87, RS232 remote control and data log
ECA 100, Analog time switch, week program
ECA 9010, Override module
BEA 0050, Auxiliary relay
300
100B
200
P16
P17
–
–
P20
P30
301
L05
L32
L66
L76
C14
C25
C35
C37
C47
C55
C60/C62
C66
C67
C75
100M
Boiler circuit Heating circuit
Hot water circuit
Others
Card
type
Cooling
circuit
Type
of circuit
*1
*1
*1
*1
*1
*1
*1
*2
A
B
C
1
2
3
4
5
6
7
ECL Comfort
1
2
3
4
5
6
7
A
B
C
A
B
C
1
2
3
4
5
6
7
ECL Comfort
1
2
3
4
5
6
7
A
B
C
A
B
C
1
2
3
4
5
6
7
ECL Comfort
1
2
3
4
5
6
7
A
B
C
Room panel
ECA 60/61/62/63
An ECA room or
remote panel for
installation in your
living room or your entrance hall makes
it possible to display and override your
ECL Comfort settings remotely.
Main features:
• Mode selection
(comfort temperature, reduced
temperature, automatic operation).
• Display of time, actual outdoor and
room temperature as well as the
lowest and highest outdoor
temperature since midnight.
• Setting of desired comfort and
reduced room temperature level
• Room temperature control via
built-in room sensor.
• Setting of periods - comfort
temperature or reduced temperature
depending on whether you are
present in the building or not.
• Setting of the service parameters:
heating cut out, minimum/
maximum room temperature
infl uence (only ECA 61/63).
• Setting of the time schedules for
the week program (only ECA 61/63).
• Humidity monitoring via built-in
humidity sensor (only ECA 62/63).
All these product features are relevant
in order to obtain the best economi-
cally and individually adjusted heating
control.
Controller and extension modules
ECL Apex 10
Extension modules
ECA-OB 003A
The following extension module must be placed on the base part in the controller. There is only room for one module.
ECA-XM 210A*
ECA-XM 205B
ECA-XM 205A
ECA-XM 204B
ECA-XM 204A
ECA-XM 102B
ECA-XM 102A
ECA-XM 101A
For temperature, pressure,
flow and energy
transmitters, etc.
Analog inputs (AI) ON/OFF outputs (DO) ON/OFF inputs (DI), opto Analog
outputs (AO)
Module with
switches
for override of
relay outputs
0-10 V d.c.
Low voltage
(max 80 V)
High voltage
(max 260 V)
Relay (SPDT)
Triac
11
8
8
8
7
8
8
8
8
8
8
3 2 2
2
X
X
4 4
Type
*) ECA-XM 210A is equipped with the M-Bus communication acc. to EN1434-3 and pulse input for frequencies up to 200 Hz.
ECL Apex 10 in SCADA
1)
systems
ECL Apex 10 can communicate with
components and systems through
RS232 communication or modem
connection. The controller operates
with a standard interface supporting
an OPC data access server (OLE for
Process Control). The OPC is used to
move data from the ECL Apex 10 to
the SCADA system enabling network
monitoring.
Power
Comm
DO1
DO2
DO3
DO4
DO5
DO6
DO7
DO8
Status
Service Tool
BUS
Alarm
Servi
ce Pin
ECL Apex 10
No. 087B2500
11 AI/ 8 DO
24 Va.c.
50/60 Hz 8 VA
MADE IN DENMARK
Service Pin
Service Tool
BUS Address
BUS
A B
24
V
a.c.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1
9
2
0
21
22
23
24
25
26
27
28
2
9
3
0
AI 8 AI 9 AI 10 AI 11
SIG
GND
SIG
GND
SIG
GND
SIG
GND
SIG
GND
SIG
GND
SIG
GND +12V +5V SHLD
SHLD
SIG
GND+1 2V +5V SHLD
SIG
GND
SIG
GND
SIG
GND SHLD
Power
Comm
1
2
3
4
5
6
7
8
Digital
Input
ECA-XM 102B
No. 087B2621
Extension 8 DIH
1
2
3
4
5
6
7
8
L
DI 1
N L
DI 2
N L
DI 3
N L
DI 4
N
Power
Comm
1
2
3
4
5
6
7
8
Relay Override
1
2
3
4
5
6
7
8
ECA-XM 205A
No. 087B2750
Extension 8 AI / DO
6
7
8
9
10
11
1
2
3
4
5
12
13
14
15
16
17
18
19
20
21
22
23
24
AI 1
SIG
GND
AI 2
SIG
GND
AI 3
SIG
GND
AI 4
SIG
GND
+12V +5V SHLD SHLD
AI 1
SIG
GND
AI 2
SIG
GND
AI 3
SIG
GND
AI 4
SIG
GND
+12V +5V S HLD SHLD
SIG
GND
SIG
GND
SIG
GND
SIG
GND
SIG
GND
SIG
GND
SIG
GND +12V +5V S HLD SHLD
Power
Comm
1
2
3
4
5
6
7
8
Digital
Input
ECA-XM 102B
No. 087B2621
Extension 8 DIH
1
2
3
4
5
6
7
8
L
DI 1
N L
DI 2
N L
DI 3
N L
DI 4
N
Power
Comm
1
2
3
4
5
6
7
8
Relay Override
1
2
3
4
5
6
7
8
ECA-XM 205A
No. 087B2750
Extension 8 AI / DO
6
7
8
9
10
11
1
2
3
4
5
12
13
14
15
16
17
18
19
20
21
22
23
24
AI 1
SIG
GND
AI 2
SIG
GND
AI 3
SIG
GND
AI 4
SIG
GND
+12V +5V SHLD SHLD
AI 1
SIG
GND
AI 2
SIG
GND
AI 3
SIG
GND
AI 4
SIG
GND
+12V +5V S HLD SHLD
SIG
GND
SIG
GND
SIG
GND
SIG
GND
SIG
GND
SIG
GND
SIG
GND +12V +5V S HLD SHLD
Select Your ECL Apex 10
1) Supervisory Control And Data Acquisition.
Kommentare zu diesen Handbüchern