This product complies with the following EC Directives
:
Electro-Magnetic Compatibility Directive.
(EMC) (89\336\EEC), (92\31\EEC)
Low Voltage Directive.
(LVD) (73\23\EEC), (93\68\EEC)
Danfoss Randall Ltd
Ampthill Road, Bedford, MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Website: www.danfoss-randall.co.uk
2 ON/OFFs
PUMPED
7 DAY or 24 HOUR
24 HOUR
3 ON/OFFs
GRAVITY
5/2 DAY
7 DAY
SW.1
SW.2
SW.3
SW.4
Installation Instructions
Product overview
The FP715 is an electronic 2-channel full programmer with independent time
base serving separate heating and hot water channels. It can be set at time of
installation for 7 day, 5/2 day or 24 hour operation. In addition the installer can
select between 2 or 3 sets of On/Off events each day. All models in the range
incorporate a permanently lit back light.
Installation
1. The product should only be installed by a qualified electrician or
competent heating installer. The installation must be in accordance with
the current edition of the IEEE wiring regulations.
2. From the top left hand corner of the wallplate there must be clearances
of at least 140mm to the right, 15mm to the left, 30mm above and 100mm
below in order to mount the plug-on module.
3. The wallplate must be securely mounted either directly to the wall,
using suitable wood screws, or to a flush mounted 1-gang electrical
accessory box using M3.5 screws.
4. Cable access can either be from behind for concealed cabling or from
below for surface cabling. If surface cable is used, cut out cable access
slot on plug-on module prior to mounting the module.
5. For wiring connections refer to Diagram 1 below. FP715 models are
double insulated and do not require an earth connection. However a parking
terminal is provided on the wallplate, which is clearly marked with an Earth
symbol.
6. Prior to mounting the plug-on module, DIL switches on the rear of the
plug-on module must be set. See Diagram 2 below for available options.
7. Mark the INSTALLER SETTING tick box on the inside flap label to
notify user in which mode their unit is set (24hr, 5/2 day or 7 day).
8. Mount plug-on module to wallplate by locating tabs on top of wallplate
in apertures on rear of module, hinge down and press firmly to wallplate
before tightening securing screws on bottom of wallplate.
CP715 FP715 (3028 12/01)
Diagram 1. - Wiring
Diagram 2. - DIL Switch Settings
Fault Check List
Event ON/OFF Mon - Fri * Sat - Sun
1 1st ON 6:30 7:30
2 1st OFF 8:30 10:00
3 2nd ON 12:00 12:00
4 2nd OFF 12:00 12:00
5 3rd ON 17:00 17:00
6 3rd OFF 22:30 22:30
* Each day if set in 24 hour mode
Product specification
Power supply 230 V ac, ±10%, 50/60 Hz
Switching action 2 x SPDT internally linked
Switch rating 230 V ac, 3(1)A
Battery back-up 24 hours minimum
Max. temperature 45°C
Programme resolution 1 minute
Dimensions, mm (W, H, D) 135 x 88 x 32
Design standard EN 60730-2-7
Control Pollution Situation Degree 2
Rated Impulse Voltage 2.5kV
Ball Pressure Test 75°C
Factory Presettings
Part No. 38033 Iss.1 03/03