Danfoss VLT HVAC Basic Drive FC 101 Spezifikationen Seite 41

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 46
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 40
1.7.4 Mains Supply 3 x 525-600 V AC
Frequency converter P2K2 P3K0 P5K5 P7K5 P11K P15K P22K P30K P45K P55K P75K P90K
Typical shaft output (kW) 2.2 3.0 5.5 7.5 11.0 15.0 22.0 30.0 45.0 55.0 75.0 90.0
Typical shaft output (hp) 3.0 4.0 7.5 10.0 15.0 20.0 30.0 40.0 60.0 70.0 100.0 125.0
IP20 frame H9 H9 H9 H9 H10 H10 H6 H6 H7 H7 H8 H8
Max. cable size in terminals (mains, motor) [mm
2
/
AWG]
4/10 4/10 4/10 4/10 10/8 10/8 35/2 35/2 50/1 50/1 95/0 120/
(4/0)
Output current
RELAY 2
130BB632.10
40°C ambient temperature
Continuous (3 x
525-550 V) [A]
4.1 5.2 9.5 11.5 19.0 23.0 36.0 43.0 65.0 87.0 105.0 137.0
Intermittent (3 x
525-550 V) [A]
4.5 5.7 10.5 12.7 20.9 25.3 39.6 47.3 71.5 95.7 115.5 150.7
Continuous (3 x
551-600 V) [A]
3.9 4.9 9.0 11.0 18.0 22.0 34.0 41.0 62.0 83.0 100.0 131.0
Intermittent (3 x
551-600 V) [A]
4.3 5.4 9.9 12.1 19.8 24.2 37.4 45.1 68.2 91.3 110.0 144.1
Max. input current
RELAY 2
130BB633.10
Continuous (3 x
525-550 V) [A]
3.7 5.1 8.7 11.9 16.5 22.5 33.1 45.1 66.5 81.3 109.0 130.9
Intermittent (3 x
525-550 V) [A]
4.1 5.6 9.6 13.1 18.2 24.8 36.4 49.6 73.1 89.4 119.9 143.9
Continuous (3 x
551-600 V) [A]
3.5 4.8 8.3 11.4 15.7 21.4 31.5 42.9 63.3 77.4 103.8 124.5
Intermittent (3 x
551-600 V) [A]
3.9 5.3 9.2 12.5 17.3 23.6 34.6 47.2 69.6 85.1 114.2 137.0
Max. mains fuses
Estimated power loss [W], Best case/typical
1)
8.4 112.0 178.0 239.0 360.0 503.0 607.0 820.0 972.0 1182.
0
1281.
0
1437.
0
Weight enclosure IP54 kg] 6.6 6.6 6.6 6.6 11.5 11.5 24.5 24.5 36.0 36.0 51.0 51.0
Efficiency [%], Best case/Typical 1 97.0 97.0 97.0 97.0 97.0 97.0 97.5 97.5 98.0 98.0 98.4 98.5
Output current
50°C ambient temperature
Continuous (3 x
525-550 V) [A]
2.9 3.6 6.7 8.1 13.3 16.1 25.2 30.1 45.5 60.9 73.5 95.9
Intermittent (3 x
525-550 V) [A]
3.2 4.0 7.4 8.9 14.6 17.7 27.7 33.1 50.0 67.0 80.9 105.5
Continuous (3 x
551-600 V) [A]
2.7 3.4 6.3 7.7 12.6 15.4 23.8 28.7 43.3 58.1 70.0 91.7
Intermittent (3 x
551-600 V) [A]
3.0 3.7 6.9 8.5 13.9 16.9 26.2 31.6 47.7 63.9 77.0 100.9
Quick Guide VLT HVAC Basic Drive Quick Guide
40 MG18A302 - VLT
®
is a registered Danfoss trademark
11
Seitenansicht 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46

Kommentare zu diesen Handbüchern

Keine Kommentare