If you wish to exclude a device from the network that does not use
the relay function of the RZ1, follow this procedure:
1. Press the PROG button, the PROG LED should turn RED.
2. Press the PROG button for at least 3 seconds or until the PROG
LED goes out.
3. Press the PROG button until the PROG LED ashes RED slowly
indication that exclusion has started.
4. Begin the exclusion process on your remote device.
5. If the process is successful the PROG LED will show solid RED.
Press PROG to return to normal operating mode.
6. If unsuccessful the PROG LED will ash ORANGE quickly. Press
the PROG button to return to step 1 and try again.
7. Once the exclusion is successfully completed, press the PROG
button to return to normal operating mode (PROG LED
GREEN).
4.3 Exclude devices not using the RZ1 relay
output from the network
If you already have a primary controller in the network and wish to
add the RZ1 as a secondary controller, follow the steps below: -
1. Place the RZ1 into programme mode by pressing the PROG
button (Programme LED will turn RED)
2. Activate the include/bind initiator on the primary controller in
the network.
3. Press and hold the programme and channel buttons until the
RED LED ashes slowly indicating that inclusion as a secondary
controller has been started.
4. The RZ1 will attempt to connect to the network.
5. Once the RZ1 has successfully been incorporated into the
network, the programme LED will return to its continuously on
RED state.
4.4 Including the RZ1 as a secondary controller