Relevant scenario Recommendation Product Energy saving Information Investment
For customers with an oil-red boiler.
Replace the old oil nozzle and remove soot
from the oil-red boiler.
Nozzle with/without LE-valve
4%
Maintenance means savings. Annual replacement of oil nozzle,
adjustment of combustion and removing soot from the oil-red
boiler optimizes combustion and reduces oil consumption.
For customers with condensing boilers. Introduce balancing. MSV-BD
10%
Improve balance to ensure that the boiler always operates in
optimal condensing mode.
For customers with condensing gas
boilers.
Replace the dial room thermostat with a
programable room thermostat.
TP5001
10%
Via the advanced time-proportional control program in
the programable room thermostat, the gas boiler is kept in
condensing mode for longer. The boiler is most ecient in
condensing mode.
For customers with electric oor heating. Install thermostats with timer. EFET 535
20%
The right temperature at the right time for electric oor heating.
For customers with hydronic oor heating.
Install individual wireless room control for
hydronic oor heating.
CF2
+
15%
The desired temperature at the right time.
For customers with radiators.
Replace manual valves or old radiator
thermostats with electronic thermostats.
living eco®
23/46%
By replacing old thermostats with our new electronic ones,
your customers can save 23% of energy used. By replacing
manual valves with electronic new living by Danfoss products,
they can save 46%.
For customers with district energy,
oil or gas boiler.
Install a weather compensator and let the
heat supply reect the outside temperature.
ECL Comfort 210
15 40%
Ensures that the heat source delivers the right temperature to
the radiator or oor heating system.
For customers who want to easily retrot
oor heating for improved comfort.
Install electric oor heating controlled
via programable thermostats or remote
controller.
Heating mat EFTM controlled via EFIT 550
25%
Fast reaction oor heating systems. The rapid response of
these systems provides the desired temperature in minutes,
providing energy savings, reduced costs and optimized
comfort.
For customers who want fast-reacting
oor heating for improved comfort.
Install SpeedUp™ light hydronic oor heating,
directly below the oor surface controlled via
the programable CF2
+
control system.
SpeedUp™ controlled via CF2
+
25%
For customers wanting improved indoor
air quality with almost no heat loss.
Install a heat recovery ventilation system. Danfoss Air Unit + Danfoss Air Flex
20%
All air is exchanged at least every 1/2 hour, controlling humidity.
Heat in the exhaust air is recovered.
For customers wanting a greener and more
energy-ecient heat source.
Replace inecient oil or gas boiler with
air/water or ground/water heat pump
(alternatively check the availability of
district heating).
DHP-H Opti Pro or DHP-AQ
50–75%
Highly ecient compared to traditional energy sources, heat
pumps can help achieve massive savings.
Share your expertise and make extra
prots by recommending the follow-
ing components to your customers
for the renovation of their heating
systems. Every small improvement
saves energy, reduces costs and in-
creases comfort. The table below
gives you an easy overview of the
possibilities, based on your custom-
er’s main heating source and budget.
Use this table to nd the products
that match their needs and the ap-
proximate energy savings they can
expect.
Great oers from you