Danfoss VLT 6000 Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 23
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
VLT
®
6000 HVAC
MD.60.A2.02 - VLT is a registered Danfoss trademark
6
Unpacking and ordering a VLT frequency
converter
Are you are in doubt as to which VLT frequency
converter you have received and which options it
contains? Use the following table to find out. The
table can also be used for ordering a VLT 6000
HVAC.
Type code ordering number string
On the basis of your order, the VLT frequency
converter is given an ordering number that can be
seen from the nameplate on the unit. The number
may look as follows:
VLVL
VLVL
VL
TT
TT
T
-6008-H-T-6008-H-T
-6008-H-T-6008-H-T
-6008-H-T
44
44
4
-B20-R3-DL-F10-A10-B20-R3-DL-F10-A10
-B20-R3-DL-F10-A10-B20-R3-DL-F10-A10
-B20-R3-DL-F10-A10
This means that the frequency converter ordered is
a VLT 6008 for three-phase mains voltage of 380-
460 V (
T4T4
T4T4
T4) in Bookstyle enclosure IP 20 (
B20B20
B20B20
B20). The
hardware variant is with integral RFI filter, classes A
& B (
R3R3
R3R3
R3). The frequency converter features a control
unit (
DLDL
DLDL
DL) with a PROFIBUS option card (
F10F10
F10F10
F10).
Character no. 8 (
HH
HH
H) indicates the application range
of the unit:
HH
HH
H = HVAC.
Bookstyle IP 20
Mains voltage, rated:
Motor power 200-240 V 380-460 V
1.1 kW VLT 6002 VLT 6002
1.5 kW VLT 6003 VLT 6003
2.2 kW VLT 6004 VLT 6004
3.0 kW VLT 6005 VLT 6005
4.0 kW VLT 6006
5.5 kW VLT 6008
7.5 kW VLT 6011
Mains voltage, rated:
Motor power 200-240 V 380-460 V
1.1 kW VLT 6002 VLT 6002
1.5 kW VLT 6003 VLT 6003
2.2 kW VLT 6004 VLT 6004
3.0 kW VLT 6005 VLT 6005
4.0 kW VLT 6006 VLT 6006
5.5 kW VLT 6008 VLT 6008
7.5 kW VLT 6011 VLT 6011
11 kW VLT 6016 VLT 6016
15 kW VLT 6022 VLT 6022
18.5 kW VLT 6027 VLT 6027
22 kW VLT 6032 VLT 6032
30 kW VLT 6042 VLT 6042
37 kW VLT 6052 VLT 6052
45 kW VLT 6062 VLT 6062
Units in the range of 1.1-45 kW come with
enclosure IP 20, IP 54.
Mains voltage, rated:
Motor power 400 V
1)
460 V
1)
55 kW VLT 6075 -
75 kW VLT 6100 VLT 6075
90 kW VLT 6125 VLT 6100
110 kW VLT 6150 VLT 6125
132 kW VLT 6175 VLT 6150
160 kW VLT 6225 VLT 6175
200 kW VLT 6275 VLT 6225
250 kW VLT 6275
Units in the range of 55-250 kW come with
enclosure IP 00, IP 20 or IP 54.
1)
The max. output depends on the mains voltage
connected to the unit.
Hardware variants
All units in the programme are available in the
following hardware variants:
ST: Standard unit w/ or w/o control unit.
RFI-filter
Bookstyle units always come with an integral RFI
filter that complies with EN 55011-1B with 20 m
screened /armoured motor cable and EN 55011-1A
with 150 m screened/armoured motor cable.
Units for a mains voltage of 240 V and a motor
power of up to and including 4.0 kW (VLT 6006) and
units for a mains voltage of 380-460 V and a motor
power of up to 7.5 kW (VLT 6011) are always
supplied with an integral class 1A & 1B filter.
Units for higher motor power than these (4.0 and
7.5 kW, respectively) can be ordered either with or
without an RFI filter.
Control unit (keypad and display)
All types of units in the programme, except for IP 54
units, can be ordered either with or without the
control unit. IP 54 units always come with a control
unit.